Fanuc DC Axis Alarms
Fanuc DC Axis Unit Alarms and Error Codes listed on this page only cover the M Series DC Axis units series 6047 (Yellow cap motors).
If your interested in finding stock of Fanuc DC Axis drive units (Velocity Control Unit).
Indication | Type | Description of Alarms |
NC | Overload | Overload alarm occurs if the motor current exceeds the current required to actuate the thermal relay. Or if the power transformer thermostat or the regenerative discharge unit thermostat operates |
TGLS | Tacho Generator | Motor speed exceeds the specified upper limit due to a break in in the velocity feedback wire, the TGLS indicator goes on. The motor is stopped by the dymanic brake. |
OVC | Over Current | Motor current exceeds the specified upper limit for more than the fixed period ( about 600 msec), the OVC indicator goes on. The motor is stopped by the dynamic brake. |
BRK | Circuit Breaker | Abnormal current exceeding the rating limit of the breaker is applied to the motor, the circuit breaker operates. The motor is stopped by the dynamic brake. |
HVAL | Over Voltage | AC input voltage applied to the servo transformer exceeds the allowable value, the HVAL indictator goes on. The motor is stopped by the dynamic brake. |
HCAL | Low Voltage | AC power source voltage drops abnormally, the LVAL indicator goes on. The motor is stopped by the dynamic brake. |
DCAL | DC Issue | Abnormal current is applied to the transistor bridge circuit, the HCAL indicator goes on. The motor is stopped by the dynamic brake. |